Shanghai Exheat Industries Co., Ltd
+86-13545529361

Plate Heat Exchanger Corrosion: Causes and Prevention Tips

Nov 02, 2026

01 | Corrosion: The Silent Killer That Can Shorten Equipment Life

When discussing common problems with plate heat exchangers, most people immediately think of leakage, fluid mixing, abnormal pressure drops, or reduced heat transfer efficiency. However, one problem is often overlooked until serious damage has already occurred: corrosion.

Unlike scale deposits, which can often be removed through cleaning, corrosion gradually damages metal from within. It is similar to termites eating away at wooden furniture. You may not notice anything at first, but once you open it up, the damage may already be extensive.

Plate heat exchanger plates are generally made of stainless steel, titanium, or Hastelloy alloys. Although these materials offer good corrosion resistance, they are not completely immune to damage. Poor operating conditions, improper cleaning methods, or incorrect material selection can still cause corrosion and eventually penetrate the plates.

Think of it like wearing a raincoat on a rainy day. You may assume you are fully protected, but if water gets into your shoes, your feet will still get wet. Corrosion works in much the same way. You may not see it happening, but its consequences can be costly.

In mild cases, corrosion can cause plate thinning and reduced heat transfer efficiency. In more severe cases, it can create pinholes or perforations in the plates, resulting in fluid cross-contamination. At its worst, corrosion can cause irreversible structural damage, leaving the entire heat exchanger beyond repair.

Corrosion damage can sometimes be repaired if detected early. However, the best way to minimize losses is to prevent it before it starts.

2026-11-02090804487

02 | Common Types of Corrosion: Small Details Can Lead to Serious Damage

Before learning how to prevent corrosion, it is important to understand what causes it.

Corrosion does not happen without a reason. Using unsuitable water, applying incorrect cleaning methods, or operating equipment improperly can all contribute to metal deterioration.

Here are four common types of corrosion you should know about:

1. Crevice Corrosion

Think of what happens when you wash your hands but forget to dry them, leaving moisture trapped beneath your watch. Over time, that area may become a breeding ground for corrosion.

In a plate heat exchanger, the contact areas between plates and gaskets, as well as the edges of the clamping frame, are particularly vulnerable. These narrow gaps can trap moisture and corrosive substances, creating conditions that promote localized corrosion.

2. Pitting Corrosion

Pitting corrosion creates small holes or cavities on the metal surface. What looks like a few tiny dark spots may actually be the beginning of serious plate damage.

It is similar to a balloon being punctured by a needle. The hole may be difficult to notice, but it can eventually cause leakage.

Pitting corrosion commonly occurs in environments with high chloride ion concentrations, especially when the selected plate material is not sufficiently resistant to chloride attack.

3. Stress Corrosion Cracking (SCC)

Stress corrosion cracking occurs when tensile stress and a corrosive environment act together over time.

In plate heat exchangers, high operating temperatures, pressure fluctuations, corrosive chemical residues, and residual stresses in the plates can contribute to crack formation.

It is like stretching a rubber band too tightly for too long. Eventually, it may suddenly snap.

This type of corrosion deserves particular attention in high-temperature applications, including pharmaceutical, food processing, and chemical industries.

4. Galvanic Corrosion (Electrochemical Corrosion)

This type of corrosion can be difficult to detect in its early stages.

When two different metals with different electrode potentials come into electrical contact in an electrolyte, an electrochemical reaction may occur. The less noble metal becomes the anode and corrodes faster.

In plate heat exchangers, incompatible material combinations and improper connections between dissimilar metals can increase the risk of galvanic corrosion.

These types of corrosion rarely develop overnight, but their consequences can be serious. The key to preventing them is not simply repairing damage after it occurs, but eliminating the underlying causes from the beginning.

03 | How to Prevent Corrosion: Practical Maintenance Tips for Longer Equipment Life

Many operators ask: How can corrosion be prevented in a plate heat exchanger?

The truth is that corrosion prevention cannot be achieved simply by adding a bottle of corrosion inhibitor. It requires proper attention at every stage, from equipment selection and cleaning to daily operation and shutdown maintenance.

Based on practical maintenance experience, the following measures can help reduce corrosion risks and extend equipment service life.

Step 1: Choose the Right Materials and Operating Media

A plate heat exchanger is not designed to handle every type of fluid or water quality.

For example, industrial wastewater containing high chloride concentrations or circulating fluids with unsuitable pH levels can seriously damage plate materials if the equipment is not properly selected.

Consider the following recommendations:

  • High-chloride environments: Consider titanium or Hastelloy plates, depending on the chloride concentration, temperature, and operating conditions.
  • Acidic media: Check the corrosion resistance of the selected plate material to ensure compatibility with the specific chemical environment.
  • Hard water or fluids containing impurities: Install suitable filtration equipment upstream to remove suspended particles and reduce the combined risks of fouling and corrosion.

Choosing the right plate material from the beginning can significantly reduce corrosion-related problems.

Step 2: Use Proper Cleaning Methods and Avoid Incompatible Chemicals

Never use hydrochloric acid indiscriminately to clean plate heat exchangers. You are maintaining precision industrial equipment, not simply cleaning a household toilet.

Before starting any chemical cleaning process, keep these points in mind:

Check the plate material before selecting a cleaning agent.

Use a compatible cleaning solution or a specially formulated chemical cleaner. Avoid strong acids that may attack the plate material.

After chemical cleaning, rinse the plates thoroughly with clean water and follow the recommended neutralization procedure to prevent chemical residues from causing further corrosion.

Improper chemical cleaning is one of the common factors that can accelerate corrosion in plate heat exchangers.

Step 3: Maintain the Equipment Properly During Shutdown

Many factories simply switch off the power and stop the pumps after production ends, leaving residual fluids, heat, and deposits inside the heat exchanger.

This is similar to leaving wet clothes in a closed space for too long. Without proper drying, unwanted deterioration can occur.

To reduce corrosion risks during shutdown:

Flush the heat exchanger with clean water before shutting it down to remove residual process fluids and deposits, where appropriate for the system.

If necessary, open the heat exchanger and allow the plates to dry, or use clean, oil-free compressed air for drying.

For long-term shutdowns, follow an appropriate preservation procedure. Depending on the equipment materials and operating conditions, this may involve suitable corrosion inhibitors or desiccants.

Proper shutdown maintenance helps prevent stagnant fluids and chemical residues from causing long-term damage.

Step 4: Perform Regular Inspections and Keep Maintenance Records

Corrosion rarely causes sudden equipment failure without any warning signs. In many cases, small changes appear first.

Pay attention to the following signs:

  • Plate discoloration or surface blistering: These may indicate early surface deterioration or localized corrosion.
  • Gradually increasing pressure drop: This may indicate fouling or deposits accumulating inside the channels, potentially creating conditions for under-deposit corrosion.
  • Unexpected changes in fluid appearance: Cloudy fluid or unusual contamination may indicate a process problem or possible internal leakage.

Experienced maintenance personnel rely on regular inspections, accurate records, and early diagnosis to identify potential problems before they develop into major failures.

The earlier corrosion-related problems are detected, the easier it is to take corrective action and minimize equipment downtime.

Final Thoughts

Corrosion is like an invisible saw, quietly cutting away at the service life of your equipment.

If you ignore it, it will gradually damage your heat exchanger plates. If you take shortcuts during maintenance, a small problem may eventually turn into a costly repair or even equipment replacement.

The key to maintaining a plate heat exchanger is to pay attention to it regularly, rather than waiting until water starts leaking before carrying out an inspection.

Effective corrosion prevention starts long before equipment failure occurs. It requires proper material selection, standardized cleaning procedures, controlled operating conditions, and regular maintenance.

A plate heat exchanger plays an important role in transferring heat throughout your production system. Keeping it operating reliably for years does not depend on luck. It depends on proper maintenance, attention to detail, and consistent operating practices.

A little preventive maintenance today can help extend plate service life and avoid costly repairs tomorrow.

Corrosion prevention is not a minor maintenance task. It is one of the keys to extending the service life of your plate heat exchanger.