Installation and operation of plate heat exchangers

May 26, 2023

Installation and operation of plate heat exchangers:

Plate heat exchangers are divided into two installation methods according to the presence or absence of saddle brackets.

 

The first, for the plate heat exchanger without saddle-type support, should be installed in the heat exchanger on the brick saddle plate, after the installation of the plate heat exchanger at this time without the saddle plate fixed, all the plate heat exchanger can be accompanied by the pescado change to move at will.

 

The second, for the plate heat exchanger with saddle rubber support, should be the first in the basic paving mix, to be fully dry after the saddle rubber support with the road mix completely fixed up with foot screws.

 

Removable plate heat exchanger plate heat exchanger installation of common problems:

1、The plate heat exchanger has 4 lifting holes for application when lifting. It is not possible to tie the rope immediately under the heat exchanger structure or plate set, and special attention should be paid to the centre of gravity point of the facility when lifting.

 

2, plate heat exchanger installation links, should be in the heat exchanger before and after the left and right sides of the empty a certain amount of indoor space to facilitate maintenance and cleaning.

 

3, before installation, check the pipeline of hot and cold material import and export is not consistent with the plate heat exchanger on the docking, in the import and export parts is best to install the temperature table and air pressure table, to facilitate timely observation of the temperature of the material, working pressure conditions.

 

4, the heat exchanger can not be higher than the factory nameplate requirements of the standard operation, for the heat exchanger clamping specifications and its heat transfer medium ambient temperature and working pressure to carry out a view and analysis, to avoid the heat exchanger found abnormal operating conditions.

 

5. If the heat transfer material is turbid or has solid particles, a filtration system needs to be installed at the material pathway pipeline;

 

6, before the start of operation, the plate heat exchanger pipeline should be unclogged and tidy to prevent welding scars or sand and gravel into the heat exchanger, resulting in blockage and damage to the heat exchanger, endangering the actual effect of heat transfer and the use of term;

 

7、If the pressure at the inlet and outlet of the pump exceeds the pressure of the heat exchanger, a regulator and valve should be installed at the inlet of the heat exchanger.